SKC Flite4 Air Sampling Pump
Portable, fully programmable, high volume air sampling pump for asbestos and other particulates.

Flite4 Air Sampling Pump Overview
The versatile SKC Flite4 Air Sampling Pump delivers high-performance air sampling for dusts, aerosols, fibres and microbes. Fully programmable and portable, the SKC Flite4 Air Sampling pump is ideal for a range of high-flow sampling applications including asbestos monitoring, long-term background monitoring, stack sampling, indoor air monitoring, biosampling and more.
The SKC Flite4 Air Sampling Pump is fully programmable to suit your sampling needs, offering manual run, timed run (with or without delayed start) or intermittent sampling. With a high capacity 7 Ah battery, and depending on the flow rate and particle size, typical runtime can exceed 12 hours. The instrument can also be powered externally through an AC mains adapter.
A backlit LCD display allows for monitoring and use in dim conditions. The robust steel casing is built to withstand everyday wear-and-tear whilst remaining conveniently portable with a sturdy, integral handle for carrying.
For more information on the Flite4 Air Sampling Pump, contact your local Air-Met Scientific office.
Flite4 Air Sampling Pump Features
- Wide flow range from 2,000 to 20,000 ml/min.
- Programmable run-times
- Manual run
- Timed run (with or without delayed start)
- Intermittent sampling
- Backlit LCD display with low battery and fault indication.
- Portable with robust steel case with integral carrying handle.
- 7 Ah high-capacity battery model for longer run times of over 12 hours at 8 L/min.
- Alternate power source capability: external high-capacity Lead-Acid battery or AC Mains
Flite4 Air Sampling Pump Specifications
Flow System |
Flow range: 2,000 to 20,000 ml/min Flow fault displayed if flow is restricted |
Power Supply |
7 Ah Rechargeable Lead-Acid battery pack, external high capacity Lead-Acid battery or AC Mains Low battery indication on LCD Charging time: 10 hours (7 Ah battery) |
Display |
Backit LCD Displays elapsed run time, timed run time, delayed start run depending on the programme Low battery and fault indication |
Operating Temperature |
-5 to 50°C (23 to 122°F) |
Case |
Steel casing with integral carrying handle |
Tubing Required |
1/4" ID |
Dimensions |
11.2 x 20.3 x 16.3 cm (4.4 x 8.1 x 7") |
Weight |
2060 g (no battery) 4260 g (fitted with 7 Ah battery) |
Flite4 Air Sampling Pump Applications
- Indoor air quality monitoring
- Asbestos monitoring
- Long-term background monitoring
- Area monitoring
- Biosampling