Series 930 Fixed Gas Transmitter and Controller
Robust IP65 Networkable Ozone Monitor.
    SKU    
    	S930    
        Series 930 Fixed Gas Transmitter and Controller Overview
The Series 930 Fixed Gas Monitor is a flexible monitor compatible with a range of gas sensors as well as a temperature and humidity sensor, if required. The sensor is housed in a robust IP65/NEMA 4 rated water resistant enclosure protecting it from water damage. There is also the option to include an integrated display for reporting real-time gas concentrations and/or an optional strobe and siren kit which can be configured to activate to a user defined set point.
The Series 930 outputs are designed to measure and control gas concentrations and communicate to a variety of hardware systems. The monitor can operate in three ways:
- As a relay controller via the integrated relays and user configurable set points to control an external device such as an ozone generator or initiate an alarm.
 - As a gas transmitter via the 4-20 mA output which allows connection to a PLC or current sensing device to provide gas concentration information for applications such as health and safety monitoring.
 - As a monitoring network via the RS485 digital output to enable gas monitoring at several indoor locations with information being logged to a central point.
 
The Series 930 monitor is easy to install due to the lightweight enclosure and provided wall mounting kit. It requires a 24V power supply which is user supplied to allow flexibility in locations it can be installed.  
For more information on the Series 930 Fixed Gas Transmitter, contact your local Air-Met office. 
Series 930 Fixed Gas Transmitter and Controller Features
- Active sampling for higher accuracy
 - Tamperproof, water-resistant enclosure
 - Multiple output transmitter
 - Real-time network capability
 - PC data logging and networking
 - Large LED local display (Optional)
 - Temperature and RH sensor (Optional)
 
Series 930 Fixed Gas Transmitter and Controller Specifications
| Measurement units | Gas: ppm or mg/m3 | Optional: Humidity: % a Temperature: °C or °F | 
| Reading functions | Instant, minimum, maximum, average | 
| Sensor head Type | Sensor head removable / replaceable | 
| Sampling method | Active sampling via internal sensor head fan | 
| Analog output | 4-20 mA (opto-isolated), 12-24 Vdc | 
| External signal type | Transistor output (4) (24 Vdc at 150 mA max) | 
| External signal functions | Low Alarm | High Alarm | Control | Diagnostics | 
| External signal input | Standby toggle | 
| Connectors | Screw type | 
| Monitor identification | 1 (Default) User configurable from 1 to 255 | 
| Alarm set points | User configurable Low Alarm | High Alarm | 
| Control set point | User configurable Low Alarm | High Alarm | 
| Communication | RS-485 (Aeroqual proprietary protocol) | 
| Software | Free PC configuration software and logging link data to a specific location and monitor (data cable required) | 
| Interface (optional) | RS-485 to USB cable | 
| Power (user supplied) | 24 Vdc, 500 mA (range 22-24 Vdc) | 
| Monitor base/enclosure material and rating | Polycarbonate | IP41 NEMA 2 equivalent | 
| Size (with sensor head L x W x H) | 180 x 110 x 90 mm 7 â…› x 4¾ x 3½ in | 
| Weight (incl. sensor) | < 850 g; < 30 oz | 
| Environmental operating conditions | 0°C to 40°C 32°F to 104°F | 
| Approvals | Part 15 of FCC Rules, EN 61000-6-3: 200, EN 61000-6-1: 2001 | 
Series 930 Fixed Gas Transmitter and Controller Applications
- Health and safety monitoring
 - Industrial process control
 - Toxic gas leak detection
 - Indoor air quality monitoring
 - Real-time network monitoring
 - Gases available: O3, VOC, H2S, NH3, SO2, NO2, CH4, or CH20