Sensitron Smart P-1 Fixed Car Park Gas Detector
A fixed car park gas detector with a precise catalytic sensor which allows for the detection of flammable compounds.
The Sensitron Smart P-1 Gas Detection System is designed to be installed in car parks and tunnels for the detection of CO and NO2. The electrochemical cell housed in a polycarbonate head can detect toxic gases and measure toxic compounds at very low concentrations of CO (0-300 ppm) and NO2 (0-30ppm) The catalytic sensor allows for the detection of flammable compounds with great precision and selectivity thus avoiding false alarms.
Stand-out features of the Sensitron Smart P-1 Car Park Gas Detector include:
- Catalytic sensors have an excellent output linearity up to 100% LFL (lower Flammability Limit) and an estimated lifetime of 4 years.
- Microprocessor in the electric circuit board is programmed with software algorithms to conduct a self-diagnostic procedure to control the detector main operational parts, both hardware and sensing elements.
If you are looking for a fixed car park gas detector that can simultaneously detect CO,NO2 gases,petrol vapours and CO check out the Sensitron SMART P-2
For more information on the Sensitron Smart P-1 Gas detector contact your local Air-Met office.
Sensitron Smart P-1 Car Park Gas Detector Features
- Standard RS485 communication
- Ongoing system self-diagnosis
- Easy sensor replacement
- IP rating: IP55
- Can operate in extreme temperatures of -20 °C and up to 50 °C
Sensitron P-1 Car Park Gas Detector Specifications
| Sensor | |||
| Application | Car Parks | ||
| Sensing element |
Electrochemical cell |
||
| Predicted sensor lifetime | EC: 2 / 3 years | ||
| Gas detected | CO, NO2 | ||
| Fullscale |
CO: 0 - 300 ppm |
||
| Electrical Data | |||
| Power supply | 12-24 Vdc | ||
| Output |
RS485 serial output |
||
| Predicted sensor lifetime | EC: 2 / 3 years | ||
| Absorption | 32 mA at 24 Vdc | ||
| Environmental conditions | |||
| Storage temperature | 0 / +20°C up to six months | ||
| Operating temperature |
-20 / +50°C |
||
| Operating humidity | 15 /90 %RH | ||
| External case | |||
| Material |
Enclosure: Polycarbonate |
||
| Dimensions |
Box: 100 x 100 x 52 mm |
||
| Weight | 250 g | ||
| Cable entries | 2 x M20 | ||
| IP Grade | IP 55 | ||
| Compliance | |||
|
EMC EN |
50270:2015 | ||
| Car park standard | EN 50545-1:2011 | ||
Sensitron Smart P-1 Car Park Gas Detector Features
To monitor toxic and flammable gas in car parks and garages